BQ-ULF-100W
WALL MOUNTED
ULTRASONIC FLOW METER
The BQ-ULF-100W wall mounted ultrasonic flow meter is designed to measure the fluid velocity of liquid within a closed conduit. The transducers are a non-contacting, clamp-on type, which will provide benefits of non-fouling operation and easy installation.the wall mounted ultrasonic flow meter utilizes two ultrasonic flow transducers that function as both ultrasonic flow transmitters and receivers. The transducers are clamped on the outside of a closed pipe at a specific distance from each other. The transducers can be mounted in V-method where the sound transverses the pipe twice, or W-method where the sound transverses the pipe four times, or in Z-method where the transducers are mounted on opposite sides of the pipe and the sound crosses the pipe once. This selection of the mounting method depends on pipe and liquid characteristics. The flow meter operates by alternately transmitting and receiving a frequency modulated burst of sound energy between the two transducers and measuring the transit time that it takes for sound to travel between the two ultrasonic flow transducers.
Product | BQ-ULF-100W Wall Mounted Ultrasonic Flow Meter |
Pipe Size | 15mm-6000mm |
Linearity | 0.5% |
Repeatability | Better than 0.2% |
Accuracy | Better than ±1% |
Power | AC220V or DC24V ; Consumption Less than 1.5W |
Accuracy | Better than ±1% |
Output | Analogue output: 4-20mA or 0-20mA current output. Impedance 0∼1k. Accuracy 0.1% |
OCT output: Frequency signal (1~9999HZ) | |
Relay output: over 20 source signal (no signal, reverse flow etc.) | |
Communication: RS485 Modbus RTU | |
Liquid | Liquid Types: Water, sea water, industrial sewage, acid & alkali liquid, alcohol, beer, all kinds of oils which can transmit ultrasonic single uniform liquid |
Temperature: Standard: -30˚C - 90˚C ,High-temperature:-30˚C - 160˚C | |
Turbidity: Less than 10000ppm, with a little bubble | |
Flow Direction | Bi-directional measuring, net flow/heat measuring |
Type | Specification | Model | Measured Pipe Size | Working temperature | Dimension |
Standard Tri-clamp Sensor | Small | TS-2 | DN15 - DN100 | -30℃~90℃ | 45*25*32mm |
Middle | TM-1 | DN50 - DN700 | -30℃~90℃ | 64*39*44mm | |
Large | TL-1 | DN300 - DN6000 | -30℃~90℃ | 97*54*53mm | |
High Tempetaure Tri-clamp Sensor | High temp/Small | TS-2-HT | DN15 - DN100 | -30℃~160℃ | 45*25*32mm |
High temp/Middle | TM-1-HT | DN50 - DN700 | -30℃~160℃ | 64*39*44mm | |
High temp/Large | TL-1-HT | DN300 - DN6000 | -30℃~160℃ | 97*54*53mm | |
Rail way Tri-clamp Sensor | Rail way/Small | HS | DN15 - DN100 | -30℃~90℃ | 318*59*85mm |
Rail way/Middle | HM | DN50 - DN300 | -30℃~90℃ | 568*59*85mm | |
Rail way/Extended | EB-1 | DN300 - DN700 | -30℃~90℃ | 188*59*49mm | |
High temperature Rail Tri-clamp Sensor | High temp rail/Small | HS-HT | DN15 - DN100 | -30℃~160℃ | 318*59*85mm |
High temp rail/Middle | HM-HT | DN50 - DN300 | -30℃~160℃ | 568*59*85mm | |
High temp rail/Large | EB-1-HT | DN300 - DN700 | -30℃~160℃ | 188*59*49mm |