loading

E-mail: michael@shboqu.com   |   Expert in Water Quality Measurement and Water Treatment Project

Skills of using the residual chlorine detector flexibly

by:BOQU     2023-03-13
The residual chlorine detector can quantitatively detect the content of residual chlorine on site, with a high degree of intelligence, simple and convenient operation. Equipped with a reference channel, the detection accuracy is high, avoiding operational errors during the detection process, and supports massive detection data storage, printing, data analysis, and chart display, and the results are simple and clear. Tips for use: 1. The reagents must be added in order in advance, and then add the blank or the water sample to be tested after mixing, otherwise the color will not develop normally. 2. It is best to compare the color immediately after adding the water sample to prevent fading. 3. Do not shake the high-concentration water sample violently to prevent free chlorine from overflowing. 4. The solution after the colorimetry is completed cannot be dumped at will, but should be collected uniformly and processed centrally. How to use: 1. Turn on the machine and preheat the machine for 2 minutes. 2. Pour the liquid to be tested into cuvette 1, and fill it to two-thirds of its volume. The process of putting in requires water stains not to reach the outside of the cuvette. Put this cuvette 1 into the measuring pool; press the calibration key to make the instrument display 0.00mg/L. 3. Take 100ML of the solution to be tested, add 15ML of the buffer reagent, add 5ML of the DPD reagent, and press the confirmation button; at this time, the screen display of the instrument decreases from 60 to 0; at this time, pour the solution to be tested with the reagent into the ratio Color cell 2; put the color cell 2 into the measuring pool, and the displayed degree is the residual chlorine content. 4. Press the storage key and the extraction key to store and extract 20 experimental records respectively. Precautions for operation of residual chlorine detector: 1. Chloride ions are not included in the measurement of residual chlorine. Chlorine measurement includes the measurement of free chlorine and combined chlorine content. 2. For the determination of free chlorine, the pH must be 6.2---6.5, and the DPD reagent should be added for direct reaction to generate a red compound. If the pH value is out of range, please adjust it with buffer reagent or dilute acid or dilute alkali. 3. The principle of the method for measuring total chlorine: when the pH is 6.2--6.5, add excess potassium iodide, add DPD to react directly, and generate a red compound. If the pH value is out of range, please adjust it with buffer reagent or dilute acid or dilute alkali. 4. The turbid sample must be filtered before measurement. 5. The color sample cannot be measured. 6. The cuvette should be cleaned and stored dry after each use.
Shanghai Boqu Instrument Co., Ltd. in the right situation can streamline the entire process, enabling your team to deliver higher quality work in a shorter amount of time.
To build customers value by delivering high-quality products, services and solutions in innovative and cost effective ways. Shanghai Boqu Instrument Co., Ltd. will realize this mission by setting the highest standards in service, reliability, safety and cost containment in our industry.
Choose the right platform for selling water analyzer and we'll reach the right customers. But if we have the right idea in the wrong platform, that still adds up to the wrong idea.
Using high technology, water analyzer showed its competitive advantages, captioned with information about the company's commitment to providing safe, reliable, profitable jobs to local artisans.
Custom message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...