E-mail: michael@shboqu.com   |   Expert in Water Quality Measurement and Water Treatment Project

The use of residual chlorine meter

by:BOQU     2023-03-31
Low configuration features of the residual chlorine analyzer: (01) The memory standard curve can be corrected by itself, and it has a power-off protection function; (02) It has a one-key calibration function, which is easy and practical to operate; (03) The optical path design of the tube colorimetric, It makes the experiment more convenient and accurate; (04) The wide optical diameter colorimetric tube is used, and the experimental colorimetric tube is combined into one. The salt test program makes the experiment more convenient, fast and accurate; the residual chlorine detector can detect residual chlorine or total chlorine; use the built-in curve correction; the residual chlorine detector has automatic turbidity, automatic color compensation and automatic diagnosis functions; a set The reagent can be used for the residual chlorine tester to run automatically for 30 days; the analysis cycle is 2.5 minutes (regular version)/10 minutes (pipe network version); the residual chlorine tester can be connected with the automatic chlorine addition pump to realize automatic chlorine addition; It can be used in unattended monitoring stations; overview of the use of the residual chlorine detector The residual chlorine detector adopts the dpd method, and uses the photoelectric colorimetric detection principle to replace the traditional visual colorimetric method. Human error is eliminated, so the measurement resolution is greatly improved. When measuring, when the tested water sample is put into the dpd tablet, the water sample will turn red. Then put the water sample into the photoelectric colorimetric seat, and the instrument will obtain the concentration of residual chlorine by comparing the shade of red. It can be applied to detect residual chlorine/total chlorine concentration of domestic or industrial water in large, medium and small water plants, industrial and mining enterprises, swimming pools, etc., so as to control the residual chlorine/total chlorine of water to meet the specified water quality standards. Features of Chlorine Meter: Streamlined appearance design, low drift, high precision circuit system, the instrument can work stably for a long time. LCD digital display, high-intensity and long-life light source, no worries about replacement, good stability, and maintenance-free. The dpd method is used for photoelectric colorimetric determination, which can measure free residual chlorine, total chlorine and combined residual chlorine.
There are many issues that affect water quality monitoring device, which has led to the need of getting specialists trained in certain areas so as to handle all issues that may arise as well as water analyzer products that can solve water quality monitoring device problems.
With comprehensive knowledge on water analyzer,why not visit the highly recommended site BOQU Water Quality Analyzer to get a full appreciation of the best ?
These water quality monitoring device water analyzer are not only useful but also more cost effective than those traditional ones.
Shanghai Boqu Instrument Co., Ltd. employs a group of professional staff, enhancing the function of water analyzer.
BOQU focuses on three key elements—process, people, and technology—the authors found that people of two seemingly opposite cultures are able to work together in a project-based environment to complement each other and reap mutual benefits for a win-win result.
Custom message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...