Advantage of Electromagnetic Flow Meter BQ-MAG
1.Measurement is not affected by the variation of flow density, viscosity, temperature, pressure and conductivity. High accuracy measurement is guaranteed according to the linear measurement principle.
2.No moving parts in the pipe, no pressure-loss and lower requirement for straight pipeline.
3.DN 6 to DN2000 covers a wide range of pipe size. A variety of liners and electrodes are available to satisfy different flow characteristic.
4.Programmable low frequency square wave field excitation, improving measurement stability and reducing power consumption.
5.Implementing 16 bits MCU, providing high integration and accuracy; Full-digital processing, high noise resistance and reliable measurement; Flow measurement range up to 1500:1.
6.High definition LCD display with backlight.
7.RS485 or RS232 interface supports digital communication.
8.Intelligent empty pipe detection and electrodes resistance measurement diagnosing empty pipe and electrodes contamination accurately.
9.SMD component and surface mount technology (SMT) are implemented to improve the reliability.
TECHNICAL PARAMETERS
Mediuim | Water,wastewater,slurry,sea water, mud and other conductivity liquids |
Diameter | DN6~DN2000mm |
Accuracy | +/-0.5% |
Temperature | <80℃(rubber); <180℃(PTFE) |
Pressure | 4.0Mpa(DN10~80); 1.6Mpa(DN100~150); 1.0Mpa(DN200~1000); 0.6Mpa(DN1200~2000) |
Flow speed | 0.3~10m/s |
Electrode | SS316L(standard); Titanium; Tantalum; Hastelloy, platinum |
Lining | PTFE; Rubber; polyurethane PUetc |
Connection | Flange; thread, tri-clamp |
Body material | Carbon steel, SS304, SS316 |
Power supply | 220VAC, 24VDC, Battery |
Output | Pulse; 4~20mA; HART; RS485; RS232, MODBUS; GPRS |
Protection | IP65 or IP68 |
SELECTION OF LINING MATERIAL
Lining Material | Features | Temperature | Typical Medium |
Neoprene(CR) | Medium abrasion resistance, general acid salt solution | <80℃ | Tap water, industrial water, sea water |
Polyurethane rubber(PU) | Excellent wear resistance and poor acid and alkali resistance | <80℃ | Slurry, pulp, mud, etc. |
PTFE(F4 or PTFE) | Stable chemical properties, corrosion resistance to boiling hydrochloric acid, sulfuric acid, aqua regia, concentrated alkali | <140℃ | Corrosive acid-base salt solution |
Polyperfluoroethylene propylene(F46 or FEP) | Chemical properties equivalent to F4, tensile strength, tensile strength better than F4 | <180℃ | Corrosive acid-base salt solution |
SELECTION OF ELECTRODE MATERIAL
Electrode | Performance |
SS316L | Suitable for: domestic water, industrial water, raw water well water, urban sewage, weak corrosive acid, alkali, salt solution |
Hastelloy B | Suitable for: non-oxidizing acid such as hydrochloric acid with concentration less than 10%, sodium hydroxide with concentration less than 50%, alkali hydroxide solution at all concentrations; phosphoric acid and organic acid; Not for: nitric acid |
Hastelloy C | Suitable for: mixed acid (such as mixed solution of chromic acid and sulfuric acid); oxidizing salts (such as seawater, containing Cu+++, Fe+++) |
Titanium | Suitable for: salt (such as chloride, sodium salt, potassium salt, ammonia salt, hypochlorite, sea water), potassium hydroxide, ammonium hydroxide, cerium hydroxide solution with concentration less than 50%; Not for: reducing acids such as hydrochloric acid, sulfuric acid, phosphoric acid, hydrofluoric acid; |
tantalum | Suitable for: hydrochloric acid (concentration less than 40%), dilute sulfuric acid and concentrated sulfuric acid (excluding fuming sulfuric acid); chlorine dioxide, ferric chloride, hypochlorous acid, sodium chloride, lead acetate, etc.; nitric acid (including fuming nitric acid) Aqueous acid), aqua regia with a temperature below 80° C; Not for: alkali, hydrofluoric acid |
Platinum | Suitable for: Almost all acid-base solutions (including fuming sulfuric acid and fuming nitric acid) |
Tungsten carbide | Suitable for: pulp, sewage, mud, resistant to solid particles |
STANDARD FLOW RANGE
Size | Flow range m³/H | Pressure | Size | Flow range m³/H | Pressure |
DN10 | 0.2-1.2 | 1.6 Mpa | DN400 | 226.19-2260 | 1.0 Mpa |
DN15 | 0.32-6 | 1.6 Mpa | DN450 | 286.28-2860 | 1.0 Mpa |
DN20 | 0.57-8 | 1.6 Mpa | DN500 | 353.43-3530 | 1.0 Mpa |
DN25 | 0.9-12 | 1.6 Mpa | DN600 | 508.94-5089 | 1.0 Mpa |
DN32 | 1.5-15 | 1.6 Mpa | DN700 | 692.72-6920 | 1.0 Mpa |
DN40 | 2.26-30 | 1.6 Mpa | DN800 | 904.78-9047 | 1.0 Mpa |
DN50 | 3.54-50 | 1.6 Mpa | DN900 | 1145.11-11450 | 1.0 Mpa |
DN65 | 5.98-70 | 1.6 Mpa | DN1000 | 1413.72-14130 | 0.6Mpa |
DN80 | 9.05-100 | 1.6 Mpa | DN1200 | 2035.75-20350 | 0.6Mpa |
DN100 | 14.13-160 | 1.6 Mpa | DN1400 | 2770.88-27700 | 0.6Mpa |
DN125 | 30-250 | 1.6 Mpa | DN1600 | 3619.12-36190 | 0.6Mpa |
DN150 | 31.81-300 | 1.6 Mpa | DN1800 | 4580.44-45800 | 0.6Mpa |
DN200 | 56.55-600 | 1.0 Mpa | DN2000 | 5654.48-56540 | 0.6Mpa |
Note: flow range,pressure can be customized |