loading

 Expert in Water Quality Measurement and Water Treatment Project Since 2007

Electromagnetic Flow Meter BQ-MAG 1
Electromagnetic Flow Meter BQ-MAG 2
Electromagnetic Flow Meter BQ-MAG 3
Electromagnetic Flow Meter BQ-MAG 4
Electromagnetic Flow Meter BQ-MAG 1
Electromagnetic Flow Meter BQ-MAG 2
Electromagnetic Flow Meter BQ-MAG 3
Electromagnetic Flow Meter BQ-MAG 4

Electromagnetic Flow Meter BQ-MAG

    oops...!

    no product data.

    Go to homepage
    Electromagnetic Flow Meter BQ-MAG 5
    Electromagnetic Flow Meter BQ-MAG 6
    Electromagnetic Flow Meter BQ-MAG 7

    ELECTROMAGNETIC FLOW METER BQ-MAG

    Advantage of Electromagnetic Flow Meter BQ-MAG

    1.Measurement is not affected by the variation of flow density, viscosity, temperature, pressure and conductivity. High accuracy measurement is guaranteed according to the linear measurement principle.

    2.No moving parts in the pipe, no pressure-loss and lower requirement for straight pipeline.

    3.DN 6 to DN2000 covers a wide range of pipe size. A variety of liners and electrodes are available to satisfy different flow characteristic.

    4.Programmable low frequency square wave field excitation, improving measurement stability and reducing power consumption.

    5.Implementing 16 bits MCU, providing high integration and accuracy; Full-digital processing, high noise resistance and reliable measurement; Flow measurement range up to 1500:1.

    6.High definition LCD display with backlight.

    7.RS485 or RS232 interface supports digital communication.

    8.Intelligent empty pipe detection and electrodes resistance measurement diagnosing empty pipe and electrodes contamination accurately.

    9.SMD component and surface mount technology (SMT) are implemented to improve the reliability.

    TECHNICAL PARAMETERS

    Mediuim

    Water,wastewater,slurry,sea water, mud and other conductivity liquids

    Diameter

    DN6~DN2000mm

    Accuracy

    +/-0.5%

    Temperature

    <80℃(rubber); <180℃(PTFE)

    Pressure

    4.0Mpa(DN10~80); 1.6Mpa(DN100~150); 1.0Mpa(DN200~1000); 0.6Mpa(DN1200~2000)

    Flow speed

    0.3~10m/s

    Electrode

    SS316L(standard); Titanium; Tantalum; Hastelloy, platinum

    Lining

    PTFE; Rubber; polyurethane PUetc

    Connection

    Flange; thread, tri-clamp

    Body material

    Carbon steel, SS304, SS316

    Power supply

    220VAC, 24VDC, Battery

    Output

    Pulse; 4~20mA; HART; RS485; RS232, MODBUS; GPRS

    Protection

    IP65 or IP68

    SELECTION OF LINING MATERIAL

    Lining Material

    Features

    Temperature

    Typical Medium

    Neoprene(CR)

    Medium abrasion resistance, general acid salt solution

    <80℃

    Tap water, industrial water, sea water

    Polyurethane rubber(PU)

    Excellent wear resistance and poor acid and alkali resistance

    <80℃

    Slurry, pulp, mud, etc.

    PTFE(F4 or PTFE)

    Stable chemical properties, corrosion resistance to boiling hydrochloric acid, sulfuric acid, aqua regia, concentrated alkali

    <140℃

    Corrosive acid-base salt solution

    Polyperfluoroethylene propylene(F46 or FEP)

    Chemical properties equivalent to F4, tensile strength, tensile strength better than F4

    <180℃

    Corrosive acid-base salt solution

    SELECTION OF ELECTRODE MATERIAL

    Electrode

    Performance

    SS316L

    Suitable for: domestic water, industrial water, raw water well water, urban sewage, weak corrosive acid, alkali, salt solution

    Hastelloy B

    Suitable for:  non-oxidizing acid such as hydrochloric acid with concentration less than 10%, sodium hydroxide with concentration less than 50%, alkali hydroxide solution at all concentrations; phosphoric acid and organic acid;

    Not for:  nitric acid

    Hastelloy C

    Suitable for: mixed acid (such as mixed solution of chromic acid and sulfuric acid); oxidizing salts (such as seawater, containing Cu+++, Fe+++)
    Not for: hydrochloric acid

    Titanium

    Suitable for: salt (such as chloride, sodium salt, potassium salt, ammonia salt, hypochlorite, sea water), potassium hydroxide, ammonium hydroxide, cerium hydroxide solution with concentration less than 50%;

    Not for:  reducing acids such as hydrochloric acid, sulfuric acid, phosphoric acid, hydrofluoric acid;

    tantalum

    Suitable for: hydrochloric acid (concentration less than 40%), dilute sulfuric acid and concentrated sulfuric acid (excluding fuming sulfuric acid); chlorine dioxide, ferric chloride, hypochlorous acid, sodium chloride, lead acetate, etc.; nitric acid (including fuming nitric acid) Aqueous acid), aqua regia with a temperature below 80° C;

    Not for:  alkali, hydrofluoric acid

    Platinum

    Suitable for:  Almost all acid-base solutions (including fuming sulfuric acid and fuming nitric acid)
    Not for: aqua regia, ammonia salt

    Tungsten carbide

    Suitable for:  pulp, sewage, mud, resistant to solid particles
    Not for:  inorganic acids, organic acids and chlorides

    STANDARD FLOW RANGE

    Size

    Flow range

    m³/H

    Pressure
    Mpa

    Size

    Flow range

    m³/H

    Pressure
    Mpa

    DN10

    0.2-1.2

    1.6 Mpa

    DN400

    226.19-2260

    1.0 Mpa

    DN15

    0.32-6

    1.6 Mpa

    DN450

    286.28-2860

    1.0 Mpa

    DN20

    0.57-8

    1.6 Mpa

    DN500

    353.43-3530

    1.0 Mpa

    DN25

    0.9-12

    1.6 Mpa

    DN600

    508.94-5089

    1.0 Mpa

    DN32

    1.5-15

    1.6 Mpa

    DN700

    692.72-6920

    1.0 Mpa

    DN40

    2.26-30

    1.6 Mpa

    DN800

    904.78-9047

    1.0 Mpa

    DN50

    3.54-50

    1.6 Mpa

    DN900

    1145.11-11450

    1.0 Mpa

    DN65

    5.98-70

    1.6 Mpa

    DN1000

    1413.72-14130

    0.6Mpa

    DN80

    9.05-100

    1.6 Mpa

    DN1200

    2035.75-20350

    0.6Mpa

    DN100

    14.13-160

    1.6 Mpa

    DN1400

    2770.88-27700

    0.6Mpa

    DN125

    30-250

    1.6 Mpa

    DN1600

    3619.12-36190

    0.6Mpa

    DN150

    31.81-300

    1.6 Mpa

    DN1800

    4580.44-45800

    0.6Mpa

    DN200

    56.55-600

    1.0 Mpa

    DN2000

    5654.48-56540

    0.6Mpa

    Note: flow range,pressure can be customized

    CONTACT US

    We will reply you in 8 hours after your message .

    no data

    Contact Us

    Contact Person:Michael Luo
    E-MAIL:michael@shboqu.com
    Tel:86-021-20965230
    Fax:86-021-20981909
    Skype:+86-15000087545
    Whatsapp:86-15000087545
    Office Add:No. 118 Xiuyan Road,Pudong New Area,Shanghai,Zip Code:201315,China

    Contact us right away

    BOQU Instrument focus on development and production of water quality analyzers and sensors, including water quality meter, dissolved oxygen meter, pH sensors, etc.

    Copyright © 2024 Shanghai BOQU Instrument Co.,Ltd | Sitemap
    Customer service
    detect