    DDG-GY

    ONLINE INDUCTIVE CONDUCTIVITY ELECTRODE

    The advantage of the common electrode type is the price, but the defect of its "polarization" is too obvious. When a current passes through the electrode, an oxidation or reduction reaction occurs, thereby changing the composition of the solution near the electrode, causing a "polarization" phenomenon, resulting in crystallized scale on the surface of the electrode. If not cleaned in time, it will cause serious errors in conductance measurement, even Damaged, the service life is not satisfactory. Even with the high-frequency alternating current measurement, it only reduces the above-mentioned polarization phenomenon. In order to maintain measurement accuracy, it must be cleaned and calibrated regularly. Every time the sensor is cleaned or replaced, it must be shut down and interrupted, which affects efficiency. Therefore, most foreign equipment uses stepless sensors.

    BOQU Instrument developed the new generation DDG-GY series inductive conductivity sensor overcomes many difficulties of the existing sensor, and integrates the signal processing line into an embedded integrated circuit ASIC with MCU, which has all the functions of conductivity measurement and digitization. This allows the sensor to be pre-calibrated before shipment and the calibration value is permanently stored in the probe.The working life can be over 10 years.

    TECHNICAL PARAMETERS

    ProductDDG-GY ONLINE INDUCTIVE CONDUCTIVITY ELECTRODE

    Maximum pressure (bar)

    1.6MP

    Electrode body materials

    PP, PFA

    Max working temperature

    200C

    Measuring range

    0~2ms/cm 0 ~ 10ms/cm, 0 ~ 20ms/cm, 0 ~ 200ms/cm, 0 ~ 2000ms/cm 

    0~10% HCL,0~10% NaOH ,25~40%NaoH,0~15%NHO3,0~30%H2SO4,92~99%H2SO4

    Accuracy (cell constant)

    ±(+25 us to measure the value of 0.5%)

    Installation

    Flow-through, pipeline, Buried

    Pipe installations

    Pipe threads 1 ½ or ¾ NPT

    Output signal

    4-20mA,RS485 Modbus,0~2000mv

    FEATURES

    Online Inductive Conductivity Electrode DDG-GY 5
    Performance in harsh chemical environments is excellent, chemical resistant material manufactured by the electrode is not polarized interference, to avoid dirt, grime and even affect fouling layer covering phenomena such as very poor, simple and easy to install so it's a very wide range of applications. Design electrodes applied to a high concentration of acids (such as fuming sulfuric acid) environment.
    Online Inductive Conductivity Electrode DDG-GY 6
    English acid concentration meter use, high accuracy, and high stability.
    Online Inductive Conductivity Electrode DDG-GY 7
    Conductivity sensor technology eliminates clogging and polarization errors. Used in all areas of contact electrodes may cause blockage which has a high performance.
    Online Inductive Conductivity Electrode DDG-GY 8
    Large aperture sensor, long-term stability./ Accommodate a wide range of brackets and use common bulkhead mounting structure, flexible installation.

    TYPICAL APPLICATION

    Online Inductive Conductivity Electrode DDG-GY 9
    Water Resources and Wastewater Treatment Engineering
    Online Inductive Conductivity Electrode DDG-GY 10
    Heating and air conditioning systems, monitoring of the condensing tower (dilution control)
    Online Inductive Conductivity Electrode DDG-GY 11
    Monitoring of metalworking process lotions
    Online Inductive Conductivity Electrode DDG-GY 12
    Monitoring of influent and sewage from sewage treatment plants
    Online Inductive Conductivity Electrode DDG-GY 13
    Washing system concentration detection before washing and beverage bottling
    Online Inductive Conductivity Electrode DDG-GY 14
    CIP line online cleaning system lotion concentration detection
    Online Inductive Conductivity Electrode DDG-GY 15
    Concentration monitoring
    Online Inductive Conductivity Electrode DDG-GY 16
    Washing liquid concentration detection for vehicle washing equipment
    no data

    Contact Us

    Contact Person:Michael Luo
    E-MAIL:michael@shboqu.com
    Tel:86-021-20965230
    Fax:86-021-20981909
    Skype:+86-15000087545
    Whatsapp:86-15000087545
    Office Add:No. 118 Xiuyan Road,Pudong New Area,Shanghai,Zip Code:201315,China

    Contact us right away

    BOQU Instrument focus on development and production of water quality analyzers and sensors, including water quality meter, dissolved oxygen meter, pH sensors, etc.

    Copyright © 2024 Shanghai BOQU Instrument Co.,Ltd | Sitemap
    Customer service
    detect