    TOCG-3040

    Online Total Organic Carbon Analyzer

    TOCG-3040 total organic carbon analyzer is an analytical instrument independently developed and produced by Hangzhou Qikun Technology Co Ltd. for the determination of total organic carbon concentration in water samples. It can detect water samples with TOC concentration from 0.001 mg/L to 100.0 mg/L, with high sensitivity and accuracy, as well as good stability. The analyzer meets a wide range of customer requirements. The software is easy to operate and can quickly analyze samples, calibrate and test the analyzer.

    TECHNICAL INDEXES

    Technical indexes of Online Total Organic Carbon Analyzer TOCG-3040

    Technical Parameters 

    ModelTOCG-3040
    Analytical methodUV persulfate oxidation-NDIR detection principle
    Measure parametersTC, IC, TOC, NPOC
    TOC range0.001 ~ 100.0 mg/L
    Low limit0.001mg/L
    Accuracy± 5% or F.S ± 0.1% (whichever is greater)
    Analysis time3 ~ 8 min
    Repeatability1.5-10mg/L Range: ≤ 3%;
    0.1-1.5mg/L Range: ≤ 5%
    Zero drift:≤ ± 2%/D
    Range drift≤ ± 2%/D
    Power supply220VAC ≤ ± 10% 50Hz ; Power: 150W
    Dimension56cm × 41cm × 146 cm



    Test conditions

    OxidizerSodium persulfate solution
    Acid reagentPhosphoric acid solution
    Carrier gasHigh-purity nitrogen (air without carbon dioxide)
    Environmental requirementsAmbient temperature: 0 ~ 40 ℃
    Relative humidity: ≤ 85%


    Online Total Organic Carbon Analyzer    TOCG-3040 5
    Online Total Organic Carbon Analyzer    TOCG-3040 6
    Online Total Organic Carbon Analyzer    TOCG-3040 7

    Online Total Organic Carbon Analyzer

    The TOCG-3040 is a compact TOC analyzer. The main components are installed on the host. Before measurement, the instrument needs to connect the gas circuit and prepare the reagent. The instrument is controlled by special software installed on the display screen of the instrument for data processing such as measurement, calibration and printing.

    Mainly application
    Water for injection and purified water;
    Cleaning validation for the pharmaceutical industry;
    Tap water and surface water;
    Chemical water (cleaning water, cooling water, reclaimed water, etc.);
    Laboratory research.

    MAIN FEATURES

    Main features of Online Total Organic Carbon Analyzer TOCG-3040

    Online Total Organic Carbon Analyzer    TOCG-3040 8
    Three detection modes: TC, TIC, TOC, NPOC, carried out in the same reactor.
    Online Total Organic Carbon Analyzer    TOCG-3040 9
    Highly reflective gold-plated gas chamber, highly concentrated infrared light source and highly sensitive infrared detector ensure excellent performance of NDIR; the data at the ppb level has sufficient sensitivity and accuracy.
    Online Total Organic Carbon Analyzer    TOCG-3040 10
    Precision metering pump to ensure the precision of the injection volume.
    Online Total Organic Carbon Analyzer    TOCG-3040 11
    Double-pass electronic condensation dehydration technology.
    Online Total Organic Carbon Analyzer    TOCG-3040 12
    Real-time visible detection curve, more intuitive.
    Online Total Organic Carbon Analyzer    TOCG-3040 13
    Real-time self-monitoring function of multiple temperature, pressure and flow.
    Online Total Organic Carbon Analyzer    TOCG-3040 14
    The curve can be formulated to meet the measurement of any water sample.
    Online Total Organic Carbon Analyzer    TOCG-3040 15
    Online Total Organic Carbon Analyzer    TOCG-3040 16
    Online Total Organic Carbon Analyzer    TOCG-3040 17

    Working principle

    TOCG-3040 total organic carbon analyzer adopts the principle of ultraviolet persulfate oxidation-NDIR detection. One sample was decomposed into CO2 by UV and persulfate oxidation, and the other sample was decomposed into CO2 by acid reagent. CO2 is dried and purified under the action of a carrier gas, and then enters a non-dispersive infrared detector (NDIR) to be measured so as to determine the carbon concentration in the sample.
    H2O + hν(185nm) →OH•+ H•
    Organic matter + OH•→CO2 + H2O

    Measurement mode

    Includes the following four measurement modes:TC 、TIC 、TOC 、NPOC

    Online Total Organic Carbon Analyzer    TOCG-3040 18
    TC mode
    The TC mode is used to determine the total carbon in the sample. The sample is decomposed into CO2 in an ultraviolet reactor under the action of an oxidant, an acid reagent and ultraviolet light.
    Online Total Organic Carbon Analyzer    TOCG-3040 19
    TIC mode
    The TIC mode is used to determine inorganic carbon (carbonate and bicarbonate) in the sample. In the ultraviolet reactor, the carbonate and bicarbonate of the sample are decomposed into CO2 under the action of acid reagent.
    Online Total Organic Carbon Analyzer    TOCG-3040 20
    TOC mode
    The TOC mode is used to determine organic carbon in the sample. TOC was determined by subtraction, i.e TOC = TC-TIC. Samples were measured for TC and TIC in turn, and the TOC measured by subtraction included volatile and non-volatile organic carbon. The TOC mode should be used when the sample contains organic compounds that are easily purged. However, TOC mode is not recommended when the TIC in the sample is much higher than TOC.
    Online Total Organic Carbon Analyzer    TOCG-3040 21
    NPOC mode
    The NPOC mode is used to determine non-purgeable organic carbon in the sample. In the ultraviolet reactor, carbonate and bicarbonate are decomposed into CO2 and purged under the action of acid reagent, while volatile organic compounds are purged out at the same time. The organic carbon fraction is then decomposed into CO2 under the action of an oxidant, an acid reagent, and ultraviolet light. The NPOC mode cannot be used when VOCs in the sample cannot be ignored.

    CONTACT US

    We will reply you in 8 hours after your message .

    no data

    Contact Us

    Contact Person:Michael Luo
    E-MAIL:michael@shboqu.com
    Tel:86-021-20965230
    Fax:86-021-20981909
    Skype:+86-15000087545
    Whatsapp:86-15000087545
    Office Add:No. 118 Xiuyan Road,Pudong New Area,Shanghai,Zip Code:201315,China

    Contact us right away

    BOQU Instrument focus on development and production of water quality analyzers and sensors, including water quality meter, dissolved oxygen meter, pH sensors, etc.

    Copyright © 2025 Shanghai BOQU Instrument Co.,Ltd | Sitemap
    Contact us
    whatsapp
    contact customer service
    Contact us
    whatsapp
    cancel
    Customer service
    detect