What are the installation requirements for the secondary water supply water quality monitoring system-Shenzhen BOQU

by:BOQU     2023-04-20
The secondary water supply water quality monitoring system needs to be installed correctly before use, and it needs to be carried out according to the correct requirements during the installation process, so as to ensure that it can play its performance in the process of using it. In order to facilitate its more Good use of this equipment, let me tell you what are the installation requirements for the secondary water supply water quality monitoring system. Installation requirements for the secondary water supply quality monitoring system 1. The secondary water supply quality monitoring system should be installed in a well-ventilated, dust-free, and dry environment. The equipment can be used in an environment with a humidity of minus ten to forty degrees. If it is used in the outdoor field, facilities such as rain shelter and lightning protection should be installed. 2. In order to facilitate subsequent maintenance and maintenance when installing the secondary water supply water quality monitoring system, a space of about 70 cm should be reserved around the equipment, and drainage ditches should be set on the surrounding ground. 3. After determining the installation location, it is necessary to do a good job of foundation treatment, and use masonry to build the tank support seat. Wait until it is completely cured before fixing the device, installing accessories and connecting the power supply. 4. Before the trial run, it is necessary to close the water supply valve and check the status of each sealing valve in the equipment. If there is leakage, it needs to be solved in time. After the equipment is started, observe the rotation direction of the machine pump. When the pressure gauge points to the top, the machine pump will Stop running and turn on the water supply pump for normal water supply. 5. The operation of the pump unit should be checked frequently. When the centrifugal pump or check valve leaks, the screws should be tightened or the asbestos roots should be replaced in time. When the pump foot bolts become loose, the equipment may be damaged. 6. Since it needs to operate the equipment through the automatic control system, it needs to avoid raining and other situations, and also needs to check whether there is a fault in the line. 7. When the paint skin of the tank body of the secondary water supply water quality monitoring system falls off, it should be painted and maintained in time to prolong its service life. The above is the introduction to the installation requirements of the secondary water supply water quality monitoring system, so when we install the equipment, we must operate according to the correct requirements, so as to ensure its normal use.
Custom message
Chat Online 编辑模式下无法使用
Leave Your Message inputting...