loading

 Expert in Water Quality Measurement and Water Treatment Project Since 2007

How to Use a pH Meter for Accurate Water Quality Measurement

Appropriate water quality is a necessity for many industries, such as drinking water systems and agricultural water. A specific parameter to measure water quality is its pH level. pH indicates the acidity or alkalinity of the water, which tells us about the balanced water chemistry. That's why the pH meter has become a precious tool. But this question may pop into your mind: How to use a pH water tester for accurate water quality measurement?


What is a pH Meter?

A pH meter is an electronic device that is used to measure the pH of a solution - it shows if it is acidic or alkaline and to what extent. The pH scale ranges from 0 to 14, with 7 being the value for natural solution. Let's talk about pH water testers. pH meters come with two primary parts: a measuring probe and a display that provides the pH reading. It has a glass electrode that measures the hydrogen ion activity in the liquid.

uploads/boquinstrument.com/images/17292451029203.png

How to Use a pH Meter - Step-by-Step

It's important to guarantee that your pH water tester is correct for the safety of industrial systems. Inaccurate pH measurement may lead to drastic results, such as improper pH levels in agriculture and pharmaceutical industries, which can ruin crops or destroy a complete batch of pharmaceuticals. The consequences are costly.

Here are the steps follow for accurate pH measurement;

1. Calibration

Before you use a pH meter, it has to be calibrated. This is not a one-time process - pH meters need regular collaborations to guarantee the accuracy of the readings. Calibration adjusts the pH water testers to known pH values. This will eliminate the risk and inaccuracies in its sensors. Here’s how to do it;

● Prepare Calibration solutions by using any buffer solutions. For example, take three solutions with pH 4, 7, and 10. Buffers have a known pH value, so the meter will see it as a reference.

● Make sure to rinse the probe with distilled water before calibrating. It will avoid any type of contamination.

● Immerse the probe of the meter. Double-check the solutions. Double-check if the sensors are fully submerged.

● Follow the steps on your pH water tester to calibrate it. Adjust it to match the known pH of the buffer solutions. Most meters allow you to calibrate at multiple points for higher accuracy.

● Don't Forget the rinse the probe again with distilled water.

 

2. Prepare the Water Sample

You are already done with the calibration; it's time to test the water sample. Use clean equipment like a beaker to collect your water sample. Make sure that the container you are using is washed with distilled water. If it is contaminated, the pH readings may alter.

pH values change with temperature, so it's important to measure the temperature of your sample as well. Alternatively, you can use an automatic temperature compensation meter that will adjust the reading itself. However, if you don't have this, you can simply measure the temperature and account for this reading.

Use a thermometer to find the temperature of your solution. Every buffer solution has a known pH value at a specific temperature. Refer to the temperature compensation charts provided by the manufacturer for your buffer solutions. It shows the changes in pH readings at different temperatures. You can manually adjust the readings.


3. Find out the Measurement

Your sample is ready so you can proceed to taking the measurement. Again, rinse the probe with distilled water. Gently place the probe into the water sample and check if it's fully submerged. It should not touch the sides of the container. This will take a few seconds to give a stable reading. Once it does, the pH value will appear on the display. After the reading gets constant, note down the results.

uploads/boquinstrument.com/images/17292451366238.png

Tips for Accurate Results

● Always use a clean probe as the dirty probe may result in a wrong response.

● Frequently calibrate your pH meter to ensure the readings are accurate. Even high-end meters must be calibrated regularly.

● Always use fresh buffer solutions that are replaced regularly for proper results.

● Avoid measuring pH at a place where temperatures are too harsh. It's better to measure at room temperature. Always store the probe in an appropriate storage solution when it's not required.


Final Thoughts

Accurate pH measurement is essential to maintain high water quality and save industries from drastic impacts. It's a critical requirement for environmental monitoring, industrial processes, and agricultural uses. The process of measuring pH is quite simple - just follow the guidelines mentioned above for accurate results. It is important to have a pH water tester that guarantees the best results. Our pH meters are tested for accurate results!


prev
Water Quality Sensor: How It Works and Its Role in Environmental Monitoring
How To Select The Right Online Turbidity Meter For Your Industry?
next
recommended for you
no data
Get in touch with us

Contact Us

Contact Person:Michael Luo
E-MAIL:michael@shboqu.com
Tel:86-021-20965230
Fax:86-021-20981909
Skype:+86-15000087545
Whatsapp:86-15000087545
Office Add:No. 118 Xiuyan Road,Pudong New Area,Shanghai,Zip Code:201315,China

Contact us right away

BOQU Instrument focus on development and production of water quality analyzers and sensors, including water quality meter, dissolved oxygen meter, pH sensors, etc.

Copyright © 2024 Shanghai BOQU Instrument Co.,Ltd | Sitemap
Customer service
detect