How to Perform Calibration Checks on Your Online Turbidity Meter

by:BOQU     2023-07-10

How to Perform Calibration Checks on Your Online Turbidity Meter


Are you relying on an online turbidity meter to ensure the quality of your drinking water or industrial processes? Like any other piece of equipment, your turbidity meter requires regular calibration checks to ensure accurate and reliable measurements.


If the turbidity readings are incorrect, you may be risking compliance issues, costly process inefficiencies, or even a public health threat. Here are some tips on how to perform calibration checks on your online turbidity meter:


1. Understand the Basics of Turbidity


Before you can calibrate your turbidity meter, it's essential to understand what turbidity is, how it's measured and why it matters. Turbidity refers to the amount of suspended particles, such as sediment, algae, and microorganisms, in a liquid. High turbidity levels can affect the aesthetic and chemical properties of water, interfere with disinfection, and cause filtration issues. Turbidity is measured in nephelometric turbidity units (NTU), and the lower the number, the clearer the liquid.


2. Determine the Right Calibration Standard


Like other measuring devices, turbidity meters need to be calibrated against known standards referred to as reference materials. The reference material must simulate the composition of the liquid you want to measure as closely as possible. While water is the most common liquid, there are different types of reference materials with varying clarity levels calibrated to meet different applications. Some of the common materials used are Formazin, StablCal, and Precision Red. Check with the manufacturer's instructions to know the right calibration standard for your meter.


3. Set up the Calibration Procedure


Calibration checks are typically done at the factory, but you still need to conduct routine checks to ensure the meter is operating within acceptable levels. The frequency of calibration checks may vary depending on your industry and application, but it's recommended to perform checks at least once a month. Calibration checks are done by performing a series of simple steps that include filling the sample chamber with the reference material, letting it stabilize, and recording the reading. Ensure that the reference material is within the acceptable level range of your meter, according to the manufacturer specifications.


4. Follow the Manufacturer's Instructions


Meters vary in terms of brands, models, and designs, and each model may have specific calibration requirements. When performing calibration checks, it's essential to follow the manufacturer's instructions on calibration procedures, standards, and acceptable ranges. Contact the manufacturer if you have any questions about your turbidity meter calibration requirement or if you're not sure about the correct procedure.


5. Record the Calibration Results


Always record the calibration results for future reference, analysis, and reporting. Keeping an accurate record can help identify any trends, detect meter drift, and show your compliance with regulations. The calibration record should include the date and time of the calibration check, calibration reference material used, results, and any corrective actions taken. Also, keep a record of any service or maintenance checks on the meter.


In conclusion, regular calibration checks are crucial to keep your online turbidity meter accurate, reliable, and compliant. Diligently following a calibration routine can help reduce the risk of inaccurate readings, increase process efficiency, and ensure the safety of your operations. By understanding the basics of turbidity, selecting the right calibration standards, following the manufacturer's instructions, and recording the calibration results, you can ensure your online turbidity meter performs to its full potential for years to come.